Tracking System

 Tracking technology
Hybrid infrared video eye- &  head-tracking Binocular & monocular tracking
 Working Volume
 centered at 600 mm distance
300 x 200 x 200 mm3 [WxHxD]
 Accuracy , static 0.5°, typical
 Accuracy , over full working volume 1°, typical
 Sampling Rate 50 Hz
 Max. head-movement velocity 15 cm/s
 Recovery-time after tracking loss
  (head was too fast or moved out of range)
40 ms
 System Dimensions ca. 300 x 45 x 80 mm3 [WxHxD]
 Mounting Options on monitor via VESA-adapter
on Tablet-PC via customized interfaces
 System Weight ca. 1,2 kg.
­

Host System

 CPU P4 class >1,4GHz
dual-core and AMD systems supported 
 RAM >512 MB (>1GB Windows VISTA)
 Interface 1 free USB-2 port
 Monitor
TFT flat screen 12" - 19" ,with VESA mount
Please ask for customized adapters for Tablet PCs, etc.
 Operating System Microsoft Windows XP SP2 or later,
Windows VISTA, Windows 7
Due to constant product improvements and localized packaging, specifications, component parts and optional equipment are subject to change without notice or obligation.­ ­
­